Can manual call point
Manual activation of fire alarms. As a means to manually trigger fire alarms, manual call points play an important part in building a strong defense against fire hazards. In stressful, dangerous situations it is essential that the alarm can be activated quickly, easily and reliably from all call points – whether they are mounted indoors or outdoors in harsh environmental conditions. Manual 'No Break' Call Point, surfaceBFSManual 'No Break' Call Point, surfaceBFS. Certified to EN54 Parts 11 (LPCB) and 13 (BSI). Smooth-action resettable element mimics the feel of breaking glass. Supplied with a red back box, reset key and ‘Not in Use’ label. Red LED ‘alarm ring’ illuminates call point face upon activation. The Norwegian norms state that the closest manual call point should be no more than 30 metres walking distance away from any point in the protected area. Although local regulations will apply, this is the minimum standard recommended by Autronica. Two main series are available: series with SelfVerify, interactive addressable manual call points.
Manual Call Points. A Break Glass Call Point is a device which enables personnel to raise the alarm by breaking the frangible element on the fascia. They should be mounted m from the floor and sited where they can be easily seen. Manual Call Points should be sited on the floor landings of stairways and at exits to open air. Manual Call Point is a device for the manual initiation of an alarm.. Manual fire alarm activation is typically achieved through the use of a pull station (term used in USA Canada) or call point (term used in Europe, Australia, and Asia), which then sounds the evacuation alarm for the relevant building or zone. Zeta CP4 Conventional Surface Mount Manual Call Point, Red. CPR Number: CPR-F Datasheet. ZT-CP4/W. Zeta CP4 Conventional Surface Mount Manual Call Point, White. ZT-CP4/Y. Zeta CP4 Conventional Surface Mount Manual Call Point, Yellow. ZT-CP3/B. Zeta CP4 Conventional Surface Mount Manual Call Point, Blue.
Product Type: Hazardous Area: Manual Alarm Call Points. The E2S hazardous location call point range contains break glass and push button types with a variety of operation modes including momentary, dual action twist and push as well as tool reset. SIL2 compliant as standard the range is available in robust marine grade aluminium, GRP or stainless steel enclosures. The first modern MCP arrived in Europe in and was developed by KAC. Manual call points are used to initiate an alarm signal, and operate by means of a simple button press or when glass is broken revealing a button. They can form part of a manual alarm system or an automatic alarm system. Manual Call Points (MCPs) (Ref BCA Ea AS AS ) are installed in buildings to perform different jobs they are available in three different colours RED, GREEN and WHITE. They are all Operated by breaking the glass pressing in the middle with items such as coins, Pens etc. RED MCP. This MCP is normally located in corridors, close to exits and on the Fire Indicator Panel (FIP).
0コメント